Related Links

  • Kavlico
  • Elsevier Ltd is not responsible for the content of external websites.

Related Stories

  • Using CFdesign to optimize performance
    A new CFdesign module, which facilitates carrying out multi-scenario design studies, has allowed Cornell Pump to spend more time on pump design, and much less time on expensive rework. CFD allows reliable simulation and optimization of the design, placement and performance of critical components, as this article shows.
  • Reliable detection at a biomass plant
    A farmers’ cooperative in Germany has been drying animal feed since 1976. They decided to retrofit their equipment after a defective seal allowed hot oil to escape on New Years Eve 2008. Allweiler provided them with new pumps and a disturbance notification device to maintain safe and reliable energy production.
  • Jets for simplified cleaning operation
    Engine wash-unit manufacturer Harry Major Machine was on the lookout for a pump that could handle recycled water containing small particles. Following a series of tests, Hydra-Cell was able to demonstrate that its products could remove carbon deposits from crankshafts and combine high levels of performance with reduced running costs.
  • Energy savings from inverter drives in the efficient building
    As our energy reserves dwindle while costs continue to rise and as the spectre of climate change looms ever larger, it becomes ever more imperative to take action on energy savings. Recent legislation is now making the route of no-action impossible. Danfoss' John Martin, strategic business area manager, HVAC put the case forward for intelligent inverter speed control of fans and pumps in buildings.
  • 50 years of World Pumps: A perspective from the inside
    To really know how the industry has changed during the lifetime of World Pumps, you have to have been a part of it. Here, we present some insights from four professionals who have witnessed and moved with the changes of five decades in the pump industry.

News

Pressure sensor for heat pumps

24 August 2009

CA-Kavlico, a global business unit of Custom Sensors & Technologies (CST) has developed a new version of its PT250 pressure transmitter designed specifically for installation in heat pump systems.

According to the EU directive 842/2006, heat pump applications using fluorinated greenhouse gases must be checked for leakage at least once every 12 months or every six months depending upon the gas quantity they contain. However, this directive does not apply to equipment with hermetically sealed systems. The PT250 from Kavlico does not utilize a gasket, and therefore complies with the directive. By installing a PT250 transmitter in the heat pump system, the end user will not need to monitor leakage rates.

Pressure ranges for the PT250 are available from 0-6 through 0-400 bar (0-100 through 0-5,000 PSI). Operating on a supply voltage of 9 to 32Vdc, the transmitters provide a 4-20mA linear analogue output that is proportional to pressure. The operating temperature range is -15° to +85°C, while storage temperature is -40° to +125°C.

 